- Manuals
- Brands
- Trane Manuals
- Heat Pump
- XR15
- Product data
Hide thumbs Also See for XR15:
- Application manual (20 pages)
Advertisem*nt
Table of Contents
- 1 Heat Pump
- 2 Product Data
- 1 Features and Benefits
- 1.1 Table of Contents
- 2 General Data
- 2.1 Product Specifications
- 2.2 A-Weighted Sound Power Level [Db(A)]
- 2.3 Accessory Description and Usage
- 2.4 AHRI Standard Capacity Rating Conditions
- 3 Model Nomenclature
- 4 Electrical Data
- 5 Dimensions
- 6 Mechanical Specification Options
- Download this manual
Split System
Heat Pump
Product Data
XR15
4TWR5
1
/
- 5 Tons
1
2
PUB. NO. 22-1832-13
Table ofContents
Advertisem*nt
Table of Contents
Related Manuals for Trane XR15
-
Heat Pump Trane SSC-APG002-EN Application Manual
Condensing units and heat pumps (20 pages)
-
Heat Pump Trane 4TTR5, 4TTR4, 4TTR3, 2TTR3, 4TWR5, 4TWR4, 4TWR3, 2TWR3 Use And Care Manual
Outdoor unit (8 pages)
-
Heat Pump Trane XL Series Use And Care Manual
Trane heat pump use and care (6 pages)
-
Xl14i split system heat pump 1,5 – 5 tons (12 pages)
-
Heat Pump TRANE XL Series Weathertron 4TWX3 Use And Care Manual
(6 pages)
-
Heat Pump Trane XL20i 4TTZ0024A1 Product Data
Split systemcooling xl20i4ttz0024, 036, 048 & 060with comfortlink 2, 3, 4 & 5 tons (12 pages)
-
Heat Pump Trane XL 15i Product Data
Split systemheat pump (16 pages)
-
Heat Pump Trane 2TWR3 Installer's Manual
(8 pages)
-
Heat Pump Trane 4TTR3 Installer's Manual
Condensing units (9 pages)
-
Heat Pump Trane 2TWB-SVU01A-EN Use And Care Manual
Trane use and care manual heat pump 2twb-svu01a-en (6 pages)
-
Heat Pump Trane 4TWR3 Installer's Manual
Heat pumps (24 pages)
-
Heat Pump Trane 4TWB3 Installation Manual
4twb3 series heat pump (8 pages)
-
Heat Pump Trane 18-BC55D1-2 Installer's Manual
Trane heat pumps installer's guide (8 pages)
-
Heat Pump Trane 2TWB0-UM-2 Use And Care Manual
Trane use and care manual heat pump 2twb0-um-2 (6 pages)
-
Heat Pump Trane WEATHERTRON 22-5156-04-0804 Use And Care Manual
Trane heat pump user manual (6 pages)
-
Heat Pump Trane 4TWR6 Series Installation And Operation Manual
(28 pages)
Summary of Contents for Trane XR15
-
Page 1: Heat Pump
Split System Heat Pump Product Data XR15 4TWR5 - 5 Tons PUB. NO. 22-1832-13... -
Page 2: Features And Benefits
• Low ambient cooling to 55°F as • Glossy corrosion resistant finish shipped • Internal compressor high/low • Extended warranties available pressure & temperature protection • 018–036 & 061 ship with start kit • Compressor Sump Heat © 2014 Trane 22-1832-13... -
Page 3: Table Of Contents
Contents Features and Benefits General Data Product Specifications A-weighted Sound Power Level [dB(A)] Accessory Description and Usage AHRI Standard Capacity Rating Conditions Model Nomenclature Electrical Data Dimensions Mechanical Specification Options 22-1832-13... -
Page 4: General Data
General Data Product Specifications Model No. 1 4TWR5018G1 4TWR5024G1 4TWR5030G1 4TWR5036G1 Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 Min Cir Ampacity Max Fuse Size (Amps) Compressors CLIMATUFF CLIMATUFF CLIMATUFF CLIMATUFF ® ® ® ® RL AMPS - LR AMPS 6.4 - 38.6 8.3 - 58 11.3 - 68.2... - Page 5 General Data Product Specifications Model No. 1 4TWR5042G1 4TWR5049E1 4TWR5061E1 Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 Min Cir Ampacity Max Fuse Size (Amps) Compressors CLIMATUFF SCROLL CLIMATUFF SCROL CLIMATUFF SCROL ® - ® - ® - RL AMPS - LR AMPS 16.7 - 112 21.8 - 117 26.4 - 134...
-
Page 6: Accessory Description And Usage
General Data Accessory Description and Usage AHRI Standard Capacity Rating Conditions AHRI STANDARD 210/240 RATING CONDITIONS — Anti-Short Cycle Timer — Solid state timing device that (A) Cooling 80°F DB, 67°F WB air entering indoor coil, prevents compressor recycling until 5 minutes have elapsed 95°F DB air entering outdoor coil. -
Page 7: Model Nomenclature
4 T W R 5 0 3 6 G 1 0 0 0 A A Outdoor Units Refrigerant Type 2 = R-22 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Product Family Z = Leadership – Two Stage... -
Page 8: Electrical Data
Electrical Data Schematic Diagrams Printed from D156994P02 22-1832-13... - Page 9 Electrical Data Schematic Diagrams 4TWR5024 Printed from D156994P02 22-1832-13...
- Page 10 Electrical Data Schematic Diagrams 4TWR5030 Printed from D156994P02 22-1832-13...
- Page 11 Electrical Data Schematic Diagrams 4TWR5036 Printed from D156994P02 22-1832-13...
- Page 12 Electrical Data Schematic Diagrams (SEE LEGEND) 4TWR5042 Printed from D156131P04 22-1832-13...
- Page 13 Electrical Data Schematic Diagrams 4TWR5049E Printed From D157471P03 22-1832-13...
- Page 14 Electrical Data Schematic Diagrams (SEE LEGEND) 4TWR5061E TDR relay cycles sump heat off dur- ing compressor operation and delays energizing the sump heat for 30 mins after “Y” call is removed. Printed From D157472P02 22-1832-13...
-
Page 15: Dimensions
Dimensions 4TWR5 Outline Drawing Note: All dimensions are in MM (Inches). MODELS BASE 4TWR5018G 730 (28-3/4) 829 (32-5/8) 756 (29-3/4) 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20) 4TWR5024G 832 (32-3/4) 829 (32-5/8) 756 (29-3/4) 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20) -
Page 16: Mechanical Specification Options
Other features include: centrifugal oil pump and low vibration and noise. 08/14 Trane Trane has a policy of continuous product and product data improvement and it reserves the right to change www.trane.com design and specifications without notice.
This manual is also suitable for:
4twr5